   T Type Continuous Working X Ray Flaw Detector
T Type X Ray Flaw Detector
Product Name:  T Type Continuous Working X Ray Flaw Detector
Model:  T Type
Views:  

Application::  Spaceflight Industry, Shipbuilding Industry, Metallurgy Industry, Chemical Industry, Power Supply, Automobiles, Pressure Container, Heavy Machine Manufacturer Industry, Bridge Building Industry, etc.

 

Brief Introduction:  T Type Portable X-ray Flaw Detector with Ceramic X-Ray Tube adopt the newest energy conversion, and rose to high-frequency operation, which make energy conversion rate improved by 30% compared with the traditional equipment, break through the traditional 1:1 working mode, no rest time requirement.

   

Features and Specifications of T Type Portable X-ray Flaw Detector with Ceramic X-Ray Tube

►Adopt the newest energy conversion, and rose to high-frequency operation, which make energy conversion rate improved by 30% compared with the traditional equipment, break through the traditional 1:1 working mode, no rest time requirement.

►Low heat, continuous working does not affect the service life.

►4000 turn all metal cooling fan make larger effective heat dissipation area; There will be no frequent over temperature protection during the full power continuous operation.

►Non flange design, small and beautiful apperance; End ring groove design make it easy to fix on the top of the pipe.

►Using high frequency paper film transformer, with strong heat resistance, low heat, High working efficiency and Low failure rate.

Model XXG/2005T XXG2505T XXG/3005T XXG/3505T
XXGHZ/2005T XXGHZ/2505T XXGHZ/3005T XXGHZ/3505T
Power Supply 160V - 255V     50 - 60HZ
Power Capacity >1.0KVA >1.5KVA >2.0KVA >2.5KVA
Tube Voltage 100KV-200KV 150KV-250KV 170KV-300KV 220KV-360KV
Tube Current 5mA

X-Ray Generator
Size (mm)Ф×H

φ165×560 φ200×590 φ230×600 φ260×650
φ165×560 φ200×590 φ230×600 φ260×650
X - Ray Beam Cone Angle 40°
40°× 360°
Controller Size(mm) 350×300×135
Controller Weight 10kg
Controller Delaying Time 0 - 1 min.
Timing Range and Error 9.9 min    Minute Error ±1%
Working Mode Continuous Working; Exposure at any time; No mandatory rest
Insulation SF6 Gas
Cooling Radiator forced air cooling
Safety Working Pressure 0.35 - 0.6 Mpa
X-Ray Generator Weight(kg) 17 24 32 34
16 23 31 33
Max. Penetration (mm) 30 40 50 75
23 34 44 70
Working Conditions of X-ray Photography 1. Focus to Film: 600mm
2. Exposure time: 5 min.

3. Film: TianJin, Model III, intensified by double lead foil.