CM10 Series Coating Thickness Gauge

Model:CM10F / CM10FH / CM10N / CM10FN
Measuring Range
CM10F :0-3000um
CM10FH:0-1000um
CM10N :0-2000um
CM10FN:0-1500um
Application:Painting, Varieties of Anti-Corrosion Coating, Powder Spraying, Plastic, Rubber, Synthetic Material, Phosphate Coating, Chromium, Zinc, Aluminum, Tin, Cadmium, Oxide Film and Phosphate Film coating thickness meaurement, etc.

Video Demo

Instruction Book Download

Brochure Download

图片关键词图片关键词

图片关键词

图片关键词

The CM10 Series Coating Thickness Gauge is a portable measuring instrument, which is designed to test the coating Quickly and accurately without damage the workpiece. It can be used for experiments and engineering field.

CM10 Series Coating Thickness Gauge meet the following standards:

GB/T 4956─2003 Non-magnetic coating on magnetic substrates, measurement of coating thickness, magnetic method

GB/T 4957─2003 Non-conductive coating thickness measurement on non-magnetic base metal Eddy current method

JB/T 8393─1996 magnetic and eddy current coating thickness measuring instrument

JJG 818─2005 Magnetic and eddy current coating thickness measuring instrument


Characteristics of CM10 series Coating Thickness Gauge


    ◆ CM10F and CM10FH adopt the magnetic measurement method, which can measure the  thickness of the non-magnetic covering layer on the magnetic metal substrate.

    ◆ CM10N adopts the eddy current measurement method to measure the thickness of the non-conductive coating on the non-magnetic metal substrate.

      ◆ CM10FN can use both magnetic measurement method and eddy current measurement method.

    ◆ CM10F measures the maximum thickness to 3mm, CM10FH measures the maximum thickness to 10mm, CM10N measures the maximum thickness to 2mm, and CM10FN measures the maximum thickness to 1.5mm.

      ◆ CM10 series coating thickness gauge can display high and low resolution.

    There are five statistics: number of measurements (N), maximum (MAX), minimum (MIN), average (MEAN) and standard deviation (STD.DEV).

      ◆ Zero point calibration, one-point calibration and two-point calibration can be used to calibrate the instrument.

      ◆ Power undervoltage alert function.

      ◆ There is a beep during operation.


Model

CM10F

CM10FH

CM10N

CM10FN

Measuring Principle

Magnetic

Magnetic

Eddy Current

Magnetic/

Eddy Current

Measuring Range (um)

0-3000

0-10000

0-2000

0-1500

Low Range Sensitivity (um)

0.1

0.1

0.1

0.1

Tolerance (um)

±(2%H+2)

±(2%H+10)

±(2%H+2)

±(2%H+2)

Testing

Condition

(mm)

Min. Measuring Surface

1.5

10

3

1

Min. Area

Diameter

7

40

5

3

Min. Substrate

Thickness

0.5

2

0.3

0.2

Display

High Contract Segment Liquid Crystal Display (LED Backlight)

Statistics

N, Max, Min, Mean and STD. DEV

Calibration

Zero, One-point Calibration and Two-Point Calibration

Working Temperature

-10℃~+50℃

Auto Power Off

After 3 minutes of inactivity

Power

2 AA Batteries

Weight

200g including batteries

Dimension

149mm×73mm×32mm (H×W×D)